From the past few years, our firm absorbed and digested sophisticated technologies equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted into the growth of Membrane Filter Water Purifier , Ultrafiltration Membrane Material , Water Treatment Filter , Our products enjoy good popularity among our customers. We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Personlized Products Tubular Membrane Module - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo Detail:
Applications
Production of mineral water, spring water, or other sterile liquid.
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient |
Effect |
SS, Particles > 1μm |
Removal Rate ≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
> 4 log |
Turbidity |
<0. 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU. This product is qualified for drinking water related products.
Product Parameters
Technical Parameters
Filtering Type |
Inside-out |
Membrane Material |
Modified PVC |
MWCO |
100K Dalton |
Membrane Area |
3.8m2 |
Membrane ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ90mm*1016mm |
Connector Size |
Φ19mm |
Application Data
Pure Water Flux |
1,200L/H (0.15MPa, 25C) |
Designed Flux |
35-100L/m2.hr (0.15MPa, 25C) |
Suggested Working Pressure |
≤ 0.2MPa |
Maximum Transmembrane Pressure |
0.2MPa |
Maximum Working Temperature |
45C |
PH Range |
Working: 4-10; Washing: 2-12 |
Operating Mode |
Cross-flow or Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil & Grease |
≤ 2mg/L |
SS |
≤ 20mg/L |
Total Iron |
≤ 1mg/L |
Continuous Residual Chlorine |
≤ 5ppm |
COD |
Suggested ≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum Backwashing Pressure |
0.2MPa |
Backwashing Flow Rate |
100-150L/m2.hr |
Backwashing Frequency |
Every 30-60min. |
Backwashing Duration |
30-60s |
CEB Frequency |
0-4 times per day |
CEB Duration |
5-10min. |
CIP Frequency |
Every 1-3 months |
Washing Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic Pollution Washing |
0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic Pollution Washing |
1-2% Citric Acid/0.2% Hydrochloric Acid |
Component Material
Component |
Material |
Membrane |
Modified PVC |
Sealing |
Epoxy Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
We persistently execute our spirit of Innovation bringing growth, Highly-quality making sure subsistence, Administration marketing reward, Credit history attracting clients for Personlized Products Tubular Membrane Module - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo , The product will supply to all over the world, such as: Kazakhstan, Ethiopia, Pakistan, With high technological support, we have tailored our website for satisfactory user experience and kept in mind your ease of shopping. we ensure that the reaches you at your doorstep, in the shortest possible time and with the help of our efficient logistical partners i.e DHL and UPS. We promise quality, living by the motto of promising only what we can deliver.