We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with al every type of product related to our product range for Membrane Bioreactor , Ultrafiltration Water , Uf Filtration , Our final goal is To try the , To be the . Please feel free to contact with us if you have any requirements.
Renewable Design for Mbr Wastewater Treatment Plant - UF Membrane Module 8 inch PVDF Ultrafiltration Membrane Module UFf200 Circuit Board Waste Water Treatment – Bangmo Detail:
Applications
Drinking water treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient |
Effect |
SS, Particles > 1μm |
Removal Rate ≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
> 4 log |
Turbidity |
< 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 25NTU.
Product Parameters
Technical Parameters
Filtering Type |
Outside-in |
Membrane Material |
Modified PVDF |
MWCO |
200K Dalton |
Membrane Area |
47m2 |
Membrane ID/OD |
0.8mm/1.3mm |
Dimensions |
Φ200mm*1710mm |
Connector Size |
DN50 Clamping |
Application Data
Pure Water Flux |
9,400L/H (0.15MPa, 25C) |
Designed Flux |
40-120L/m2.hr (0.15MPa, 25C) |
Suggested Working Pressure |
≤ 0.2MPa |
Maximum Transmembrane Pressure |
0.15MPa |
Maximum Backwashing Pressure |
0.15MPa |
Air Washing Volume |
0.1-0.15N m3/m2 .hr |
Air Washing Pressure |
≤ 0.1MPa |
Maximum Working Temperature |
45C |
PH Range |
Working: 4-10; Washing: 2-12 |
Operating Mode |
Cross-flow or Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.
Turbidity |
≤ 25NTU |
Oil & Grease |
≤ 2mg/L |
Suspended Solids |
≤ 20mg/L |
Total Iron |
≤ 1mg/L |
Continuous Residual Chlorine |
≤ 5ppm |
COD |
Suggested ≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Backwashing Flow Rate |
100-150L/m2.hr |
Backwashing Frequency |
Every 30-60min. |
Backwashing Duration |
30-60s |
CEB Frequency |
0-4 times per day |
CEB Duration |
5-10min. |
CIP Frequency |
Every 1-3 months |
Washing Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic Pollution Washing |
0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic Pollution Washing |
1-2% Citric Acid/0.2% Hydrochloric Acid |
Component Material
Component |
Material |
Membrane |
Modified PVDF |
Sealing |
Epoxy Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Sincerity, Innovation, Rigorousness, and Efficiency is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for Renewable Design for Mbr Wastewater Treatment Plant - UF Membrane Module 8 inch PVDF Ultrafiltration Membrane Module UFf200 Circuit Board Waste Water Treatment – Bangmo , The product will supply to all over the world, such as: Malta, Lyon, Oslo, We have many years' experience in hair product production, and our strict QC Team and skilled workers will ensure that we give you high quality hair products with the high hair quality and workmanship. You will get successful business if you choose to cooperate with such a professional manufacturer. Welcome your order cooperation!